Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 394

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 396

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 398

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 400

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 406

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 406

Warning: Illegal string offset 'areaCode' in /home/intsiglent/public_html/include/header.php on line 406

Warning: Illegal string offset 'areaCode' in /home/intsiglent/public_html/include/header.php on line 406
SIGLENT: Home / Support / Downloads
SSA3000X Plus Firmware Update
Version: V3.2.2.6.2R5
2024-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
1. New Functionality:
  • Add Picture Viewer
  • Add Open Source Acknowledge
  • Add Remote Control Mode, when entering, the interface displays system time, limit status, system messages, etc., shielding UI refresh. SCPI: DISPlay:WINDow:ENABle ON|OFF
  • Save the configuration every 60 seconds, and load it when Power On is turned Last
  • SA mode Limit Setup adds Fail to Save, which automatically saves screenshot and trace data when the Limit Test result is Fail.  It can only be used when Fail to Stop is turned ON 
2. Improvements:
  • Preset optimization: When pressing the Preset button, it will first jump to the Preset menu instead of directly performing Preset; Touch Assist's Preset adds preset option
  • Optimization System Info display content
  • When taking screenshots, do not capture the message indicating successful screenshot
  • Limit the length of numbers entered on the screen and keypad
  • Add SCPI commands to read system messages:SYSTem:MESSage?
  • Added screenshot function under the Help window
  • Set the FFT menu to invalid when the SA mode cannot select FFT
  • SA mode can open the Freq Counter for markers other than marker 1
  • The SA mode peak table displays the peak of the current trace
  • The SA mode peak table displays the peak of the current trace, rather than the current marker’s trace
  • The dBc parameter range of the SA mode OBW is changed to negative numbers
  • When Noise Marker is turned on in SA mode, set Detect Type to Average
  • In SA/MA/EMI mode, Wait for Trigger is displayed only if Trigger is not triggered for 2 seconds.
  • When using markers in SA/MA/EMI modes, display the marker info enlarged in the upper left corner of the screen
  • SA/EMI mode display more information of limit fail and pass
  • The MA mode supports the SCPI command: TRACe#[:DATA]? to get trace data
  • SCPI command for setting marker X in MA mode: TRACe#:MARKer#:X supports specifying time units 
3. Solved Issues:
  • Fix the problem of the inconsistency between the numerical accuracy displayed in SA mode Freq menu Ref Offset and the status bar on the left
  • Fix the problem of Marker display unit error when Noise Marker is turned on in SA mode
  • Fix the problem of the SCPI command TRACe#:MODE in the SA mode setting trace type, which causes a crash when the selected trace exceeds the range.
  • Fix the problem of not adding Freq Offset to the marker x value in SA mode
  • Fix the problem of Correction errors when switching between X-Scale Lin and Log in SA mode
  • Fix the problem of inconsistent units and settings for values obtained by SCPI commands :DISPlay:WINDow:TRACe:Y:RLEVel? in SA/EMI mode
  • Fix the problen where Sweep Time may be incorrect when set EqLPF to Auto in MA mode
SSA3000X Plus Series Firmware Update
Version: V3.2.2.6.0R7
2023-06-09
SSA3000X Plus Firmware Update
Version: V3.2.2.5.1R1
2022-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
Improvements:
  • Optimize the Ref level and Att couple
  • Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
  • Add .trc file in EMI Mode
  • Add .lic file auto scan
 
Solved Issues:
  • Fix pi/4 DPSK和pi/8 DPSK decode errors in MA mode
  • Fix fft frequency error in narrow span in SA mode
  • Fix trace avg calculation error in SA mode
  • Fix the zero sweep type when fft in SA mode
SSA3000X Plus Firmware Update
Version: 3.2.2.5.0
2021-11-26
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
New Functionality:
  • Added Ext Trigger Delay from 0-10 seconds in SA Mode
 
Solved Issues:
  • Fixed the difference between marker and peak and marker style;
  • Fixed Center Freq error;
  • Fixed limit fail to stop error;
  • Fixed Auto frequency error;
  • Fixed in normalization, auto re-normalized after any setting changes
  • EMI frequency offset error; saving std lim path error
  • Web browser cannot change IP, and cannot login after changing password
SSA3075X Plus Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3021/3032X Plus Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3015X Plus Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3075X Plus Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
SSA3021/3032X Plus Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
SSA3015X Plus Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
SSA3021/3032X Plus Firmware Update
Version: V3.2.2.3.2
2020-09-18
Release notes
Solved Issues:
  • Fix avg power bug in EMI Mode
  • Fix amplitude bug in AMA Mode
  • Fix peak search bug in SCPI command
SSA3015X Plus Firmware Update
Version: V3.2.2.3.2
2020-09-18
Release notes
Solved Issues:
  • Fix avg power bug in EMI Mode
  • Fix amplitude bug in AMA Mode
  • Fix peak search bug in SCPI command
SSA3021/3032X Plus Firmware Update
Version: V2.2.1.2.8
2020-07-24
Release notes
New Functionality:
• Update EMI option to a new EMI measurement mode
Improvements:
• Improve TG output harmonic performance
• Update Help file
Solved Issues:
• Fix ADC overload warning
• Fix Ch Power calculation bug in small span
SSA3021/3032X Plus Firmware Update
Version: V2.2.1.2.7
2020-05-29
Release notes
Notice:
This firmware must be upgraded from V2.1.1.1.12a or later. If your SVA1000X has an earlier version, please update to V2.1.1.1.12a first and then proceed to update to the latest version.
 
Improvements:
  • Add Limit mask offset in SA mode
  • TG Level adjustable in Reflection Meas
 
Solved Issues:
  • Fixed AM and FM symbol rate error, Lpf coefficient error, in AMA mode
  • Fixed Filter bandwidth error in DMA mode
  • Fixed Freq counter error in SA mode
  • Fixed Harmonic error in SA mode
  • Help Display error 