SIGLENT: Home / Support / Downloads
SDS2000X-E Series Firmware Update
Version: V1.1.20R6
2024-02-22
Release notes
  1. Fixed the bug: The average of measurement is mistake for 35M points
  2. Optimized the time of auto-setup
SDS2000X-E Series Firmware Update
Version: V1.1.20R3
2022-09-16
Release notes
1.   Compatible new hardware
SDS2000X-E Series Firmware Update
Version: V1.1.19R5
2020-07-03
Release notes
1. Added support for the SAG1021I USB Isolated AWG Module Hardware
2. Fixed the bug: Sometimes PNSU command returns invalid value (Need referring to the latest Program Guide)
3. Added 9 data bits for UART decoding
4. Fixed the bug of UART decoder with some special settings
5. Increased baud rate of UART trigger from 5 Mbps to 20 Mbps
6. Fixed the bug: The command ‘WF? DAT2’returns error length of waveform when digital is enable
7. Fixed the bug: CSV file of waveform has no indication of the trigger point in the data
8. Fixed the bug: After repowering all FFT markers are on just one peak
9. Fixed the bug: After repowering, signal level of CAN trigger can't be recalled
10. Fixed a few SCPI Commands errors:
MATH: CURSOR_VALUE?
C3:INVERT_SET? is missing
HISTORY_LIST? is missing
DIGITAL:LOW8_SWICHT, typo in name
C5:COUPLING? typo in name
11. Fixed the Bode Plot bug: Sometime there isn't enough delay after the scope switches timebase values before it tries to take a measurement
12. Fixed the bug: Matlab can’ t import 14 M Matlab waveform files
13. Fixed the bug:‘WF?’ command ignores the length set by ‘WFSU’ for digital
SDS2000X-E Series Firmware Update
Version: V1.1.19R2
2019-09-12
SLA1016 Firmware
Version: V8.1.16
2019-05-23
SDS2000X-E Series Firmware Update
Version: V1.1.17R6
2019-03-27
Release Notes
Release Notes
Tel:
+86-755-36887876
Address:
Bldg No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, China