Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 394

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 396

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 398

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 400

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 406

Warning: Illegal string offset 'nation' in /home/intsiglent/public_html/include/header.php on line 406

Warning: Illegal string offset 'areaCode' in /home/intsiglent/public_html/include/header.php on line 406

Warning: Illegal string offset 'areaCode' in /home/intsiglent/public_html/include/header.php on line 406
SIGLENT: Home / Support / Downloads
SVA1000X Firmware Update
Version: V3.2.2.6.3R2.r2
2025-06-13
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
  • Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW (only SVA1075X).
  • Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
  • Optimize the auto-save function, add the auto-save switch and auto-save time function to Last Preset.
  • Add SCPI command, you can use the pscpi command to set/query the reference clock source used by the machine.
  • Improve the measurement function, including increasing the number of markers in VNA mode to 14; optimize the measurement accuracy of the channel power measurement mode to ensure higher measurement accuracy.
Solved Issues:
  • Fixed some known defects.
SVA1000X Firmware Update
Version: V3.2.2.5.1R1
2022-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
Improvements:
  • Optimize the Ref level and Att couple
  • Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
  • Add Cable Atten to correct cable loss in DTF Mode
  • Add .trc file in EMI Mode
  • Add .lic file auto scan
 
Solved Issues:
  • Fix pi/4 DPSK和pi/8 DPSK decode errors in MA mode
  • Fix calibration error when port extension on in VNA mode
  • Fix fft frequency error in narrow span in SA mode
  • Fix trace avg calculation error in SA mode
  • Fix the zero sweep type when fft in SA mode
SVA1000X Firmware Update
Version: V3.2.2.5.0
2021-12-03
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
New Functionality:
  • Added Ext Trigger Delay from 0-10 seconds in SA Mode
  • Added Limit in Log mag and Lin mag format;
  • Added calibration average;
  • Added s1p touchstone file save in VNA mode
 
Improvements:
  • VNA sweep points up to 10001; Scale down to 0.001 in Smith chart;
  • MA Filter type Nyquist change to Raised Cosine to align SCPI command; improve filter performance in low frequency
  • EMI RBW/Step from 1 to 3
 
Solved Issues:
  • SA mode:
Fixed the difference between marker and peak and marker style;
Fixed Center Freq error; Fix limit fail to stop error;
Fixed Auto frequency error;
Fixed In normalization, auto re-normalized after any setting changes
  • VNA mode:
Fixed Phase error;
Fixed STA file saving error;
Fixed CSA file loading error;
Fixed S21 calibration error;
Fixed Enhanced calibration error
  • EMI mode:
Fixed Frequency offset error;
Fixed Saving std lim path error
  • Web browser cannot change IP, and cannot login after changing password
SSA3000X Plus Firmware Update
Version: V3.2.2.6.3R2.r2
2025-06-13
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
  • Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW(only SSA3075XPlus).
  • Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
  • Fixed some known defects.
SSA3000X Plus Firmware Update
Version: V3.2.2.6.2R5
2024-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
1. New Functionality:
  • Add Picture Viewer
  • Add Open Source Acknowledge
  • Add Remote Control Mode, when entering, the interface displays system time, limit status, system messages, etc., shielding UI refresh. SCPI: DISPlay:WINDow:ENABle ON|OFF
  • Save the configuration every 60 seconds, and load it when Power On is turned Last
  • SA mode Limit Setup adds Fail to Save, which automatically saves screenshot and trace data when the Limit Test result is Fail.  It can only be used when Fail to Stop is turned ON 
2. Improvements:
  • Preset optimization: When pressing the Preset button, it will first jump to the Preset menu instead of directly performing Preset; Touch Assist's Preset adds preset option
  • Optimization System Info display content
  • When taking screenshots, do not capture the message indicating successful screenshot
  • Limit the length of numbers entered on the screen and keypad
  • Add SCPI commands to read system messages:SYSTem:MESSage?
  • Added screenshot function under the Help window
  • Set the FFT menu to invalid when the SA mode cannot select FFT
  • SA mode can open the Freq Counter for markers other than marker 1
  • The SA mode peak table displays the peak of the current trace
  • The SA mode peak table displays the peak of the current trace, rather than the current marker’s trace
  • The dBc parameter range of the SA mode OBW is changed to negative numbers
  • When Noise Marker is turned on in SA mode, set Detect Type to Average
  • In SA/MA/EMI mode, Wait for Trigger is displayed only if Trigger is not triggered for 2 seconds.
  • When using markers in SA/MA/EMI modes, display the marker info enlarged in the upper left corner of the screen
  • SA/EMI mode display more information of limit fail and pass
  • The MA mode supports the SCPI command: TRACe#[:DATA]? to get trace data
  • SCPI command for setting marker X in MA mode: TRACe#:MARKer#:X supports specifying time units 
3. Solved Issues:
  • Fix the problem of the inconsistency between the numerical accuracy displayed in SA mode Freq menu Ref Offset and the status bar on the left
  • Fix the problem of Marker display unit error when Noise Marker is turned on in SA mode
  • Fix the problem of the SCPI command TRACe#:MODE in the SA mode setting trace type, which causes a crash when the selected trace exceeds the range.
  • Fix the problem of not adding Freq Offset to the marker x value in SA mode
  • Fix the problem of Correction errors when switching between X-Scale Lin and Log in SA mode
  • Fix the problem of inconsistent units and settings for values obtained by SCPI commands :DISPlay:WINDow:TRACe:Y:RLEVel? in SA/EMI mode
  • Fix the problen where Sweep Time may be incorrect when set EqLPF to Auto in MA mode
SSA3000X Plus Series Firmware Update
Version: V3.2.2.6.0R7
2023-06-09
SSA3000X Series Firmware Update
Version: V2.1.1.4
2023-09-08
Release notes
Notice:
This firmware must be upgraded from v2.1.1.1 or later. If your analyzer has an earlier version, don’t use this FW to update.

Solved Issues:
• Fix the problem that the bandwidth of the emi filter in SA mode
• Fix the problem that setting the TG Level in SA mode may cause TG to have no output
• Fix the problem that the n dB Marker measurement results in SA mode are inconsistent with the OBW measurement results
• Fix the problem that there is an invalid frequency menu in Harmonic in SA mode
• Fix an issue where 'micro' relative units represented by 'u' were not recognized when reading files
SSA3000X Plus Firmware Update
Version: V3.2.2.5.1R1
2022-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
Improvements:
  • Optimize the Ref level and Att couple
  • Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
  • Add .trc file in EMI Mode
  • Add .lic file auto scan
 
Solved Issues:
  • Fix pi/4 DPSK和pi/8 DPSK decode errors in MA mode
  • Fix fft frequency error in narrow span in SA mode
  • Fix trace avg calculation error in SA mode
  • Fix the zero sweep type when fft in SA mode
SSA3000X Series Firmware Update
Version: V2.1.1.3R1
2022-09-16
Release notes
Notice:
This firmware must be upgraded from v2.1.1.1 or later. If your analyzer has an earlier version, don’t use this FW to update.
 
Improvements:
  • Optimize the Ref level and Att couple
 
Solved Issues:
  • Fix the zero sweep type when fft in SA mode
  • Fix the OPC response in EMI mode
SSA3000X Plus Firmware Update
Version: 3.2.2.5.0
2021-11-26
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
New Functionality:
  • Added Ext Trigger Delay from 0-10 seconds in SA Mode
 
Solved Issues:
  • Fixed the difference between marker and peak and marker style;
  • Fixed Center Freq error;
  • Fixed limit fail to stop error;
  • Fixed Auto frequency error;
  • Fixed in normalization, auto re-normalized after any setting changes
  • EMI frequency offset error; saving std lim path error
  • Web browser cannot change IP, and cannot login after changing password
SSA3000X Series Firmware Update
Version: V 1.3.9.10
2024-02-05
Release notes
1. This firmware must be upgraded from V1.2.8.1 or later, V2.X.X.X versions are not supported for upgrading this firmware. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
2. Fixed the error in setting RBW in EasySpectrum when using emi filter.
3. Optimize the settable range of Ref Level. When the maximum value of Correction data that is turned on is positive, the maximum settable Ref Level is correspondingly increased by an equal value.
4. Fixed TOI measurement marked error.
5. Fixed the issue of possible crash when using the scpi command [:SENSe]:CORRection:CSET#:DATA? to read Correction data.
6. Optimize the use of command :DISPlay:WINDow:TRACe:Y[:SCALe]:RLEVel to set Ref Level. If no unit is specified, the current amplitude unit is used as the unit.
7. Fixed the issue where the command :CALCulate:MARKer#:Y? may read Marker amplitude value incorrectly when using Video Trigger.
8. Add Peak to Center command
   :CALCulate:MARKer#:MAXimum:CENTer
SSA3000X Series Firmware Update
Version: V1.3.9.8
2021-08-16
Release notes
  1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
  2. Compatible with different batches hardware
SSA3075X Plus Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3000X Series Firmware Update
Version: V1.3.9.7
2021-03-26
Release notes
  1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
  2. Fixed the LOG scale sweep time and display error
  3. Fixed the trace file .trc load and display error
  4. Improve the stability of TG
  5. Add peak excursion require command
:CALCulate:MARKer:PEAK:EXCursion?

Add sweep state require command
:TRACe:SWEep:STATe?

Add N dB Bandwidth left and right frequency require command
:CALCulate:MARKer*:BANDwidth:RLEFt?
:CALCulate:MARKer*:BANDwidth:RRIGht? 
SSA3021/3032X Plus Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3015X Plus Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3000X Series Firmware Update
Version: V1.3.9.6
2020-10-22
Release notes
  1. This firmware must be upgraded from V1.2.8.1 or later. If your SSA3000X has an earlier version, please update to V1.2.8.1 first and then proceed to update to the latest version.
  2. Fixed the problem unit in TG and the UNCAL condition
  3. Fixed the AVG detector in frequency LOG scale
  4. Fixed the display error with long file name
  5. Fixed some SCPI commands
  6. Fixed the beeper switch
  7. Fixed the .cor file error when recalling it
  8. Add Limit mask offset in frequency and amplitude
SSA3075X Plus Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
SSA3000X Series Firmware Update
Version: V1.2.9.3a
2019-05-29
SSA3000X-R Firmware Update
Version: V3.2.2.6.3R2
2025-06-13
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
New Functionality:
  • Add measurement related functions, including:APSK function, Marker Band function, MA Record function and 200 Hz EMI RBW.
  • Add system related functions, including: local oscillator feedthrough self calibration, 10M out frequency accuracy Self-Calibration function and FTP function.
Improvements:
  • Optimize the auto-save function, add the auto-save switch and auto-save time function to Last Preset.
  • Add SCPI command, you can use the pscpi command to set/query the reference clock source used by the machine.
  • Improve the measurement function, including increasing the number of markers in VNA mode to 14; optimize the measurement accuracy of the channel power measurement mode to ensure higher measurement accuracy.
Solved Issues:
  • Fixed some known defects.
SSA3021/3032X Plus Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
SSA3000X Series Firmware Update
Version: V1.2.9.2a
2018-11-19
SSA3000X-R Firmware Update
Version: V3.2.2.6.2R5
2024-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
1. New Functionality:
  • Add Picture Viewer
  • Add Open Source Acknowledge
  • Add Remote Control Mode, when entering, the interface displays system time, limit status, system messages, etc., shielding UI refresh. SCPI: DISPlay:WINDow:ENABle ON|OFF
  • Save the configuration every 60 seconds, and load it when Power On is turned Last
  • SA/VNA mode Limit Setup adds Fail to Save, which automatically saves screenshot and trace data when the Limit Test result is Fail.  It can only be used when Fail to Stop is turned ON 
2. Improvements:
  • Preset optimization: When pressing the Preset button, it will first jump to the Preset menu instead of directly performing Preset; Touch Assist's Preset adds preset option
  • Optimization System Info display content
  • When taking screenshots, do not capture the message indicating successful screenshot
  • Limit the length of numbers entered on the screen and keypad
  • Add SCPI commands to read system messages:SYSTem:MESSage?
  • Added screenshot function under the Help window
  • Set the FFT menu to invalid when the SA mode cannot select FFT
  • SA mode can open the Freq Counter for markers other than marker 1
  • The SA mode peak table displays the peak of the current trace
  • The SA mode peak table displays the peak of the current trace, rather than the current marker’s trace
  • The dBc parameter range of the SA mode OBW is changed to negative numbers
  • When Noise Marker is turned on in SA mode, set Detect Type to Average
  • In SA/MA/EMI mode, Wait for Trigger is displayed only if Trigger is not triggered for 2 seconds.
  • Add Display Line in VNA/DTF/MA/RTSA/EMI mode
  • When using markers in SA/VNA/DTF/MA/EMI modes, display the marker info enlarged in the upper left corner of the screen
  • SA/EMI mode display more information of limit fail and pass
  • Return more marker information when using SCPI command :CALCulate#:MARKer#:Y? in SA mode
  • The MA mode supports the SCPI command: TRACe#[:DATA]? to get trace data
  • SCPI command for setting marker X in MA mode: TRACe#:MARKer#:X supports specifying time units 
3. Solved Issues:
  • Fix the problem of the inconsistency between the numerical accuracy displayed in SA mode Freq menu Ref Offset and the status bar on the left
  • Fix the problem of Marker display unit error when Noise Marker is turned on in SA mode
  • Fix the problem of the SCPI command TRACe#:MODE in the SA mode setting trace type, which causes a crash when the selected trace exceeds the range.
  • Fix the problem of not adding Freq Offset to the marker x value in SA mode
  • Fix the problem of Correction errors when switching between X-Scale Lin and Log in SA mode
  • Fix the problem of inconsistent units and settings for values obtained by SCPI commands :DISPlay:WINDow:TRACe:Y:RLEVel? in SA/EMI mode
  • Fix the problen where Sweep Time may be incorrect when set EqLPF to Auto in MA mode
  • Fix the problem of Max Hold error in RTSA mode
SSA3015X Plus Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option
Solved Issues:
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix amplitude error in DMA Mode
• Fix upgrade failure issue
SSA3000X Series Firmware Update
Version: V1.2.9.1
2018-05-25
SSA3000X-R Firmware Update
Version: V3.2.2.4.0
2021-01-21
Release notes
  • This version can not be rolled back
  • Fix TG switch error at small RBW
  • Fix Help and Limit file lost when Factory reset
  • Fix Auto open delay unit error in VNA mode
  • Fix CNR calc error when no peak found
  • Fix OBW result overflow
  • Fix Harmonic calc error at 100Hz RBW
  • Fix Reflection Open+Short calibration action
  • Fix spectrum amplitude error in DMA mode
  • Optimize EMI .csv file content to all signal list
  • Optimize EMI peak search
  • Optimize Auto cal process
  • Add Peak search to Spectrum in DMA mode
SSA3000X Series Firmware Update
Version: V1.2.8.5a
2017-09-22
SSA3000X-R Firmware Update
Version: V3.2.2.3.3R1
2020-12-11
Release notes
New Functionality:
• Add EMI filter in SA for EMI option

Solved Issues:
• Optimize the response in RTSA
• Optimize the TG flatness and control procedure
• Optimize Help
• Fix Correction, .csv file, add peak numbers to 20 in EMI mode
• Fix ADC overload warning error, and time unit error in Calibration in VNA Mode
• Fix amplitude error in DMA Mode
• Fix the frequency band downgrade to 3.2GHz on some units
• Fix upgrade failure issue
SSA3021/3032X Plus Firmware Update
Version: V3.2.2.3.2
2020-09-18
Release notes
Solved Issues:
  • Fix avg power bug in EMI Mode
  • Fix amplitude bug in AMA Mode
  • Fix peak search bug in SCPI command
SSA3000X Series Firmware Update
Version: V1.2.8.3
2017-06-26
SSA3015X Plus Firmware Update
Version: V3.2.2.3.2
2020-09-18
Release notes
Solved Issues:
  • Fix avg power bug in EMI Mode
  • Fix amplitude bug in AMA Mode
  • Fix peak search bug in SCPI command
SSA3000X Series Firmware Update
Version: V1.2.8.2
2017-02-23
SSA3000X-R Firmware Update
Version: V3.2.2.6.0R7
2023-06-08
SSA3021/3032X Plus Firmware Update
Version: V2.2.1.2.8
2020-07-24
Release notes
New Functionality:
• Update EMI option to a new EMI measurement mode
Improvements:
• Improve TG output harmonic performance
• Update Help file
Solved Issues:
• Fix ADC overload warning
• Fix Ch Power calculation bug in small span
SSA3000X Series Firmware Update
Version: V1.2.8.1
2016-11-09
SSA3000X-R Firmware Update
Version: V3.2.2.5.1R1
2022-06-28
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
Improvements:
  • Optimize the Ref level and Att couple
  • Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
  • Add Cable Atten to correct cable loss in DTF Mode
  • Add .trc file in EMI Mode
  • Add .lic file auto scan
 
Solved Issues:
  • Fix the false signals in density view in RTSA mode
  • Fix pi/4 DPSK和pi/8 DPSK decode errors in MA mode
  • Fix calibration error when port extension on in VNA mode
  • Fix fft frequency error in narrow span in SA mode
  • Fix trace avg calculation error in SA mode
  • Fix the zero sweep type when fft in SA mode
SSA3021/3032X Plus Firmware Update
Version: V2.2.1.2.7
2020-05-29
Release notes
Notice:
This firmware must be upgraded from V2.1.1.1.12a or later. If your SVA1000X has an earlier version, please update to V2.1.1.1.12a first and then proceed to update to the latest version.
 
Improvements:
  • Add Limit mask offset in SA mode
  • TG Level adjustable in Reflection Meas
 
Solved Issues:
  • Fixed AM and FM symbol rate error, Lpf coefficient error, in AMA mode
  • Fixed Filter bandwidth error in DMA mode
  • Fixed Freq counter error in SA mode
  • Fixed Harmonic error in SA mode
  • Help Display error 
SSA3000X Series Firmware Update
Version: V1.2.7.7
2016-07-14
SSA3000X-R Firmware Update
Version: V3.2.2.5.0
2021-12-08
Release notes
Notice:
This firmware must be upgraded from V3.2.2.4.0 or later. If your analyzer has an earlier version, please update to V3.2.2.4.0 first and then proceed to update to the latest version.
 
New Functionality:
  • Add Ext Trigger Delay from 0-10 seconds in SA Mode
  • Add Limit in Log mag and Lin mag format; add calibration average; add s1p touchstone file save in VNA mode
 
Improvements:
  • VNA sweep points up to 10001; Scale down to 0.001 in Smith chart;
  • MA Filter type Nyquist change to Raised Cosine to align SCPI command; improve filter performance in low frequency
EMI RBW/Step from 1 to 3
 
Solved Issues:
  • SA mode:
Fixed the difference between marker and peak and marker style;
Fixed center Freq error;
Fixed limit fail to stop error;
Fixed auto frequency error;
Fixed in normalization, auto re-normalized after any setting changes
  • VNA mode:
Fixed phase error;
Fixed STA file saving error;
Fixed CSA file loading error;
Fixed S21 calibration error;
Fixed enhanced calibration error
  • RTSA mode:
Fixed continue peak preset error;
Fixed Freq step error
  • EMI mode:
Fixed frequency offset error;
Fixed saving std lim path error
  • Web browser: Fixed change IP error, Login error after changing password
2019-11-25
SSA3000 Series Firmware Update
Version: V1.2.7.3
2016-03-30
SSA3000X Series Firmware Update
Version: V2.1.1.6R5.r7
2025-06-13
SSA5000A Firmware Update
Version: V1.9.0.2.2R3
2025-05-27
Release notes
New Functionality:
  • Add user calibration for reference clock
Improvements:
  • SA mode: optimize refresh efficiency
  • AMA mode: optimize AF smoothing effect
  • NF mode: exporting table results as .csv files
  • Add FTP switch function
Solved Issues:
  • SA mode: align estimated scan time and regular scan time
  • BT mode: solve issues including Preset, EDR signal demodulation, and no response to quick operations
  • PN mode: solve issues including signal averaging failure and incorrect sweep width
  • NF mode: solve issues including calculation errors
  • RTSA mode: solve issues including no waveform in screenshots, peak failure, failure to save and load files, and missing reference offset
  • Add and modify SCPI commands:
1. Period cursor reading error (:CALCulate:MARKer:FCOunt:X?)
2. Query cursor function returns off (CALCulate:MARKer:FUNCtion?)
3. Setting external trigger command is inconsistent with programming manual (:TRIGger[:SEQuence]:SOURce)
4. Harmonic analysis command is missing to obtain each order harmonic frequency and power and obtain total harmonic distortion
(:READ:HARMonics:AMPLitude:ALL? :READ:HARMonics:DISTortion?)
5. SA command reads back cent, low, high.Q results when obtaining NDB results(:CALCulate:MARKer:BANDwidth:RESult?)
SHA850A Firmware Update
Version: V1.8R1
2025-01-17
Release notes
New Functionality:
•Added EMI mode.
•Added SCPI commands to query files in a specified directory.

Improvements:
•Optimized the system information interface.
•Supports saving measurement results in txt format under AMA and DMA Mode.
•Optimized the calculation accuracy of Band Marker.

Solved Issues:
•Fix DHCP failure after IP conflict.
•Fix IQ collection.
•Fix map compression package reading error,and the playback points displaying error.
SHA850A Firmware Update
Version: V1.7R5
2024-07-11
Release notes
Added open source agreement description.
SSA5000A Firmware Update
Version: V.1.1.2.2.0
2024-03-12
Release notes
New Functionality:
  • Add Phase Noise Measurement Mode
  • Add Noise Figure Measurement Mode
  • Add Pulse Measurement Mode
  • Add Blue Tooth Analysis Mode
  • Add AF spectrogram, SNR,Dist/Total,THD parameter analysis results in AMA Mode
  • Add image browsing in SYSTEM 
Solved Issues:
  • EMI mode Scan Only rescan with one less count issue
  • EMI mode sending command unable to rescan meter and Meas issues
SHA850A Firmware Update
Version: V1.7R2
2024-03-12
Release notes
New Functionality:
  • Add GNSS timing.
  • Add the outdoor map downloader software EasyMAP.
  • Add automatic screenshot and data store for LIMIT. 
Improvements:
  • UI Response improvement 
Solved Issues:
  • Fixed small RBW display.
  • Fixed the abnormality of warm drifting calibration (compatible with old machines: calculating two problems with errors).
  • When the DTF is solved to the feet format, the cursor returning unit is the problem of YARDS.
SHA850A firmware update
Version: V2.1.2.1.6R5
2024-01-16
Release notes
New Features:
•Kml recording function.
•Supports importing maps.
•Supports map feature under Channel Power measurement record playback in SA mode.

SCPI Commands:
•Added [ [:SENSe]:WAVeform:POINts? ] command to obtain the number of IQ sampling points.
•Added [ :FETCh:WAVeform? ] command to obtain IQ collected waveform data.

Optimized Function:
•Optimized the Channel Power measurement refresh response efficiency in SA mode.
•Optimized VNC refresh efficiency.

Solved Problem:
•Fixed unstable frequency counter in SA mode.
•Fixed audio demodulation buzzing sound in SA mode.
•Fixed when trace is view in SA mode, a large error will be obtained when executing alignment.
•Fixed incorrect sequence number when harmonics obtain fundamental wave amplitude in SA mode.
SHA850A Firmware Update
Version: V1.1.2.1.5R0
2023-08-28
Release notes
New Functionality:
• VNA new format: Unwrap Phase/Real/Imaginary
• VNA trace: Z Reflection

Improvements:
• Optimize the Ref level and Att couple
• Add SCPI commands in MA Mode
•READ:ADEMod:AVG?
•[:SENSe]:ADEMod:FM:DEVI?
•[:SENSe]:ADEMod:FM:DRIFt?
•[:SENSe]:BWIDth[:RESolution]
•[:SENSe]:BWIDth[:RESolution]?
•[:SENSe]:BWIDth:EQLPf
•[:SENSe]:BWIDth:EQLPf?
•CALCulate:MARKer#:PTPeak
• Add Cable Atten to correct cable loss in DTF Mode
• Add .trc file in EMI Mode
• Add .lic file auto scan

Solved Issues:
• Fix pi/4 DPSK和pi/8 DPSK decode errors in MA mode
• Fix calibration error when port extension on in VNA mode
• Fix fft frequency error in narrow span in SA mode
• Fix trace avg calculation error in SA mode
• Fix the zero sweep type when fft in SA mode
SSA5000A Firmware Update
Version: 1.1.2.1.7R3
2023-08-28
Release notes
Improvements:
• Support EMI mode
• VNC interface optimization
Solved Issues:
• The default detection type of the third-order intermodulation in SA mode is changed to Pos
• Fixed cursor readout update error when the readout type is not auto
• 10db higher signal amplitude under harmonic analysis
• Harmonic analysis cannot modify the number of harmonics
• Solved the problem that FTP cannot be used
• MA mode time domain graph marker display unit corrected to dBV
Release Notes
Release Notes
Tel:
006-04-3998964
Address:
NO.6 LORONG JELAWAT 4 KAWASAN PERUSAHAAN SEBERANG JAYA 13700, PERAI PULAU PINANG, Malaysia